<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Road Laboratory (Bitumen and bituminous binder) - SOCIETE NOUVELLE DU LITTORAL</title>
	<atom:link href="https://www.standard-sand.com/en/categorie-produit/road-laboratory-bitumen-and-bituminous-binder/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.standard-sand.com/en/categorie-produit/road-laboratory-bitumen-and-bituminous-binder/</link>
	<description>Depuis plus de 100 ans</description>
	<lastBuildDate>Fri, 29 May 2026 07:00:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.standard-sand.com/wp-content/uploads/2025/11/Standard-sand-logo-100x100.png</url>
	<title>Road Laboratory (Bitumen and bituminous binder) - SOCIETE NOUVELLE DU LITTORAL</title>
	<link>https://www.standard-sand.com/en/categorie-produit/road-laboratory-bitumen-and-bituminous-binder/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SAND FOR HYDROCARBON BINDERS NF T 66-061</title>
		<link>https://www.standard-sand.com/en/produit/sand-for-hydrocarbon-binders-nf-t-66-061/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Thu, 22 Jan 2026 08:49:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/sand-for-hydrocarbon-binders-nf-t-66-061/</guid>

					<description><![CDATA[<p>Anhydrous binder antistripping efficiency test USAGE Essai d’efficacité du dopage des liants anhydres    CHARACTERISTICS The sand is natural siliceous sand with a water content lower than 0.1 %. The constituent grains are uncrushed and round-shaped. They have a silica content higher than 98%. It is packaged in polyethylene bag of 1000 ± 10 g.&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/sand-for-hydrocarbon-binders-nf-t-66-061/">Continue reading <span class="screen-reader-text">SAND FOR HYDROCARBON BINDERS NF T 66-061</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/sand-for-hydrocarbon-binders-nf-t-66-061/">SAND FOR HYDROCARBON BINDERS NF T 66-061</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong>Anhydrous binder antistripping efficiency test</strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph">Essai d’efficacité du dopage des liants anhydres   </p>

<h2 class="wp-block-heading">CHARACTERISTICS</h2>

<p class="wp-block-paragraph">The sand is natural siliceous sand with a water content lower than 0.1 %. The constituent grains are uncrushed and round-shaped. They have a silica content higher than 98%.</p>

<p class="wp-block-paragraph">It is packaged in polyethylene bag of 1000 ± 10 g.</p>

<p class="wp-block-paragraph">Deliveries are made in boxes of 20 bags weighing 20.5 kg and in pallets of 36 to 45 boxes with a gross weight of 750 to 935 kg, suitably protected by a polyethylene cover (road transport) or reinforced boxes (international).</p>

<h2 class="wp-block-heading">CONTROLS</h2>

<p class="wp-block-paragraph">Grading requirement of this sand is fixed by NF T 66-061. It corresponds to 0.1/0.63. The sand average grading is:</p>

<figure class="wp-block-table is-style-stripes"><table class="has-fixed-layout"><thead><tr><th class="has-text-align-center" data-align="center">Square mesh size in (mm)</th><th class="has-text-align-center" data-align="center"></th><th class="has-text-align-center" data-align="center">Cumulative passing (%)</th><th class="has-text-align-center" data-align="center"></th></tr></thead><tbody><tr><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">Average grading</td><td class="has-text-align-center" data-align="center"><strong>SNL spécifications</strong></td><td class="has-text-align-center" data-align="center"><strong>NF T 66061</strong></td></tr><tr><td class="has-text-align-center" data-align="center">1.25</td><td class="has-text-align-center" data-align="center">100</td><td class="has-text-align-center" data-align="center">100</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.63</td><td class="has-text-align-center" data-align="center">100</td><td class="has-text-align-center" data-align="center">90 to 100</td><td class="has-text-align-center" data-align="center">maxi</td></tr><tr><td class="has-text-align-center" data-align="center">0.5</td><td class="has-text-align-center" data-align="center">98.8</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.315</td><td class="has-text-align-center" data-align="center">48.7</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.2</td><td class="has-text-align-center" data-align="center">9</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.1</td><td class="has-text-align-center" data-align="center">1</td><td class="has-text-align-center" data-align="center">0 à 10</td><td class="has-text-align-center" data-align="center">mini</td></tr><tr><td class="has-text-align-center" data-align="center">0.08</td><td class="has-text-align-center" data-align="center">0.4</td><td class="has-text-align-center" data-align="center">0 à 1</td><td class="has-text-align-center" data-align="center"></td></tr></tbody></table></figure>

<p class="wp-block-paragraph">Grading is controlled by 200 kg of sand. Water content is measured by 1000 kg batches.</p>

<h2 class="wp-block-heading"><strong>CONFORMIT</strong><strong>Y</strong></h2>

<p class="wp-block-paragraph">Controls are carried out by SNL Laboratory.</p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/sand-for-hydrocarbon-binders-nf-t-66-061/">SAND FOR HYDROCARBON BINDERS NF T 66-061</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silica Fines S.N.L for Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. Equivalent Forshammer coefficient of 0.94.</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines-s-n-l-for-rupture-index-of-cationic-bitumen-emulsions-irec-en-13075-1-equivalent-forshammer-coefficient-of-0-94/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Wed, 21 Jan 2026 16:18:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/silica-fines-s-n-l-for-rupture-index-of-cationic-bitumen-emulsions-irec-en-13075-1-equivalent-forshammer-coefficient-of-0-94/</guid>

					<description><![CDATA[<p>Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. CHARACTERISTICS The silica fines S.N.L for breaking index of emulsions EN 13075 1-2 is a fine sand of the same origin as the old Sikaisol -Annex B Following the stock shortage of SIKAISOL sand, the S.N.L developed and perfected a sand that could meet the requirements&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines-s-n-l-for-rupture-index-of-cationic-bitumen-emulsions-irec-en-13075-1-equivalent-forshammer-coefficient-of-0-94/">Continue reading <span class="screen-reader-text">Silica Fines S.N.L for Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. Equivalent Forshammer coefficient of 0.94.</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-s-n-l-for-rupture-index-of-cationic-bitumen-emulsions-irec-en-13075-1-equivalent-forshammer-coefficient-of-0-94/">Silica Fines S.N.L for Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. Equivalent Forshammer coefficient of 0.94.</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong>Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1.</strong></p>

<h2 class="wp-block-heading">CHARACTERISTICS</h2>

<p class="wp-block-paragraph">The silica fines S.N.L for breaking index of emulsions EN 13075 1-2 is a fine sand of the same origin as the old Sikaisol -Annex B</p>

<p class="wp-block-paragraph">Following the stock shortage of SIKAISOL sand, the S.N.L developed and perfected a sand that could meet the requirements of the standard &#8216;Determination of the breaking index of cationic bitumen emulsions, Mineral fines method&#8217; EN 13075 1-2 by applying a Forshammer correction coefficient of 0.94.</p>

<p class="wp-block-paragraph">Important notice: According to the EN 13075-1 standard, there are 3 standardized reference products on the market: Forshammer, Sikaisol and Q92; the S.N.L. product is not yet integrated into the standard as a replacement for Sikaisol.</p>

<p class="wp-block-paragraph">The advantage of this new sand is its replicability.</p>

<ul class="wp-block-list">
<li>The silica content is stable at +98% (which is a guarantee of stability of the chemistry compared to products composed of different materials)</li>



<li>The production is carried out in a mechanical and industrial way (screened and mixed): this allows us to ensure the physical stability of the product</li>
</ul>

<p class="wp-block-paragraph">The product is available in 5 kg or 25 kg buckets</p>

<h2 class="wp-block-heading"><strong>CONTROL</strong></h2>

<p class="wp-block-paragraph">With each manufacturing batch is associated a certificate of conformity ensuring compliance with the table:</p>

<figure class="wp-block-table"><table class="has-fixed-layout"><thead><tr><th class="has-text-align-center" data-align="center">Ouverture en mm</th><th class="has-text-align-center" data-align="center">% passant cumulé</th><th class="has-text-align-center" data-align="center">Tolérance produit</th></tr></thead><tbody><tr><td class="has-text-align-center" data-align="center">0.315</td><td class="has-text-align-center" data-align="center">100.00</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.25</td><td class="has-text-align-center" data-align="center">99.90</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.2</td><td class="has-text-align-center" data-align="center">98.51</td><td class="has-text-align-center" data-align="center">+/-2</td></tr><tr><td class="has-text-align-center" data-align="center">0.16</td><td class="has-text-align-center" data-align="center">96.00</td><td class="has-text-align-center" data-align="center">+/-2</td></tr><tr><td class="has-text-align-center" data-align="center">0.125</td><td class="has-text-align-center" data-align="center">91.00</td><td class="has-text-align-center" data-align="center">+/-2</td></tr><tr><td class="has-text-align-center" data-align="center">0.1</td><td class="has-text-align-center" data-align="center">78.00</td><td class="has-text-align-center" data-align="center">+/-5</td></tr><tr><td class="has-text-align-center" data-align="center">0.08</td><td class="has-text-align-center" data-align="center">48.00</td><td class="has-text-align-center" data-align="center">+/-5</td></tr><tr><td class="has-text-align-center" data-align="center">0.063</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.05</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0.04</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr><tr><td class="has-text-align-center" data-align="center">0</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td></tr></tbody></table></figure>

<p class="wp-block-paragraph">For each production batch, we guarantee you a certificate of conformity guaranteeing compliance with the table:</p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-s-n-l-for-rupture-index-of-cationic-bitumen-emulsions-irec-en-13075-1-equivalent-forshammer-coefficient-of-0-94/">Silica Fines S.N.L for Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. Equivalent Forshammer coefficient of 0.94.</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Reference fines Q92 EN13075-1</title>
		<link>https://www.standard-sand.com/en/produit/reference-fines-q92/</link>
		
		<dc:creator><![CDATA[oppg-leucate]]></dc:creator>
		<pubDate>Wed, 21 Jan 2026 15:50:06 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/reference-fines-q92/</guid>

					<description><![CDATA[<p>Method of determination of the Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. The standardized reference fines Q92 (formerly Kaolin Q92) are indicated in the standard for determining the Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1. According to the EN 13075-1 standard, there are 3 standardized reference filers on the market: Forshammer, Sikaisol&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/reference-fines-q92/">Continue reading <span class="screen-reader-text">Reference fines Q92 EN13075-1</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/reference-fines-q92/">Reference fines Q92 EN13075-1</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong>Method of </strong><strong>determin</strong><strong>ation of </strong><strong>the Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1.</strong></p>

<p class="wp-block-paragraph">The standardized reference fines Q92 (formerly Kaolin Q92) are indicated in the standard for determining the Rupture Index of Cationic Bitumen Emulsions (IREC) EN 13075-1.</p>

<p class="wp-block-paragraph">According to the EN 13075-1 standard, there are 3 standardized reference filers on the market: Forshammer, Sikaisol and Q92.</p>

<p class="wp-block-paragraph">Q92 is packaged in hermetic 25 kg buckets after sampling, sieving and homogenization. Each batch is accompanied by a certificate of particle size analysis produced by an independent materials study centre to guarantee compliance with the particle size range of the standard.</p>

<h2 class="wp-block-heading">DELIVERY</h2>

<ul class="wp-block-list">
<li>COFRAC batch granulometric analysis certificate (Included in the bucket) with batch identification on each bucket</li>



<li>Hermetic metal bucket with strapping ring</li>



<li>EN 13075-1</li>



<li>Sampled, Sieved, Homogenized</li>



<li>Net weight: 25 kg</li>
</ul>
<p>L’article <a href="https://www.standard-sand.com/en/produit/reference-fines-q92/">Reference fines Q92 EN13075-1</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GLASS SPHERES ACCORDING TO NF EN 13036-1</title>
		<link>https://www.standard-sand.com/en/produit/glass-spheres-according-to-nf-en-13036-1/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Wed, 21 Jan 2026 15:02:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/glass-spheres-according-to-nf-en-13036-1/</guid>

					<description><![CDATA[<p>Method Measurement of the porosity of bitumen’s USAGE Measurement of the average depth of the macro-texture surface of a road surface (road and airport), using a volumetric technique on site according to standard EN 13036-1 concerning tests related to pavements&#13; &#13; Note: NF EN 13036-1 replaced the old standard NF P98-216-1 whose control material was&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/glass-spheres-according-to-nf-en-13036-1/">Continue reading <span class="screen-reader-text">GLASS SPHERES ACCORDING TO NF EN 13036-1</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/glass-spheres-according-to-nf-en-13036-1/">GLASS SPHERES ACCORDING TO NF EN 13036-1</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong>Method Measurement of the porosity of </strong><strong>bitumen’s</strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph">Measurement of the average depth of the macro-texture surface of a road surface (road and airport), using a volumetric technique on site according to standard EN 13036-1 concerning tests related to pavements&#13;
&#13;
Note: NF EN 13036-1 replaced the old standard NF P98-216-1 whose control material was a sand HSV and of which SNL still has stock in bags of 1KG)</p>

<p class="wp-block-paragraph">The method can be used on a wide range of surfaces. Nevertheless, caution should be exercised in the interpretation of results when the measured depth is outside the interval (0.25 – 5 mm) <strong>  </strong></p>

<h2 class="wp-block-heading">CHARACTERISTICS</h2>

<p class="wp-block-paragraph">The glass beads, fully spherical and calibrated, are clean, dry, prepared in a modern workshop offering all guarantees of quality and regularity.</p>

<h2 class="wp-block-heading">DELIVERY</h2>

<p class="wp-block-paragraph">These glass beads are packaged in buckets of 5 kg and 15 kg and sold as articles:</p>

<ul class="wp-block-list">
<li>Set of 5 buckets of 5 kg</li>



<li>Set of 10 buckets of 5 kg</li>



<li>Set of 4 buckets of 15 kg</li>
</ul>

<p class="wp-block-paragraph">Each order is delivered on a pallet with plastic film protection.</p>

<h2 class="wp-block-heading">CONTROLES</h2>

<p class="wp-block-paragraph">The particle size determined by sieving complies with the requirements of standard NF-EN 13036-1: at least 90% of the weight of the balls has a diameter between 0.18 and 0.25 mm</p>