<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Reference Materials - SOCIETE NOUVELLE DU LITTORAL</title>
	<atom:link href="https://www.standard-sand.com/en/categorie-produit/reference-materials-and-reference-sand/reference-materials-2/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.standard-sand.com/en/categorie-produit/reference-materials-and-reference-sand/reference-materials-2/</link>
	<description>Depuis plus de 100 ans, Matériaux pour laboratoire ciment, béton, granulat &#38; route</description>
	<lastBuildDate>Tue, 18 Aug 2026 14:18:27 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.standard-sand.com/wp-content/uploads/2025/11/Standard-sand-logo-100x100.png</url>
	<title>Reference Materials - SOCIETE NOUVELLE DU LITTORAL</title>
	<link>https://www.standard-sand.com/en/categorie-produit/reference-materials-and-reference-sand/reference-materials-2/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Silica Fines  D50=3µ</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines-d5013%c2%b5-copie/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 12:52:52 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1404</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Silica Ultra-Fines can be used in the control of permeability fineness measuring equipment. The product is nevertheless not referenced in the standard NF EN 196-6. GENERAL INFORMATION ABOUT SILICA ULTRA FINES Silica Ultra Fines are produced industrially by crushing The silica content is higher than 99%. The&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines-d5013%c2%b5-copie/">Continue reading <span class="screen-reader-text">Silica Fines  D50=3µ</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-d5013%c2%b5-copie/">Silica Fines  D50=3µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra-Fines can be used in the control of permeability fineness measuring </span><span dir="ltr" role="presentation">equipment. The product is nevertheless not referenced in the standard NF EN 196-6.</span></p>

<h2 class="wp-block-heading">GENERAL INFORMATION ABOUT SILICA ULTRA FINES</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra Fines are produced industrially by crushing</span> <br role="presentation"/><span dir="ltr" role="presentation">The silica content is higher than 99%. </span> <br role="presentation"/><span dir="ltr" role="presentation">The density of 2.65 is measured by pycnometer. </span> <br role="presentation"/><span dir="ltr" role="presentation">Fineness is a statistically calculated value.</span></p>

<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-d5013%c2%b5-copie/">Silica Fines  D50=3µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silica Fines  D50=13µ</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines-d5018%c2%b5-copie/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 12:51:08 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1402</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Silica Ultra-Fines can be used in the control of permeability fineness measuring equipment. The product is nevertheless not referenced in the standard NF EN 196-6. GENERAL INFORMATION ABOUT SILICA ULTRA FINES Silica Ultra Fines are produced industrially by crushing The silica content is higher than 99%. The&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines-d5018%c2%b5-copie/">Continue reading <span class="screen-reader-text">Silica Fines  D50=13µ</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-d5018%c2%b5-copie/">Silica Fines  D50=13µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra-Fines can be used in the control of permeability fineness measuring </span><span dir="ltr" role="presentation">equipment. The product is nevertheless not referenced in the standard NF EN 196-6.</span></p>

<h2 class="wp-block-heading">GENERAL INFORMATION ABOUT SILICA ULTRA FINES</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra Fines are produced industrially by crushing</span> <br role="presentation"/><span dir="ltr" role="presentation">The silica content is higher than 99%. </span> <br role="presentation"/><span dir="ltr" role="presentation">The density of 2.65 is measured by pycnometer. </span> <br role="presentation"/><span dir="ltr" role="presentation">Fineness is a statistically calculated value.</span></p>

<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-d5018%c2%b5-copie/">Silica Fines  D50=13µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silica Fines D50=18µ</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines-copie-copie/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 12:46:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1400</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Silica Ultra-Fines can be used in the control of permeability fineness measuring equipment. The product is nevertheless not referenced in the standard NF EN 196-6. GENERAL INFORMATION ABOUT SILICA ULTRA FINES Silica Ultra Fines are produced industrially by crushing The silica content is higher than 99%. The&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines-copie-copie/">Continue reading <span class="screen-reader-text">Silica Fines D50=18µ</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-copie-copie/">Silica Fines D50=18µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra-Fines can be used in the control of permeability fineness measuring </span><span dir="ltr" role="presentation">equipment. The product is nevertheless not referenced in the standard NF EN 196-6.</span></p>

<h2 class="wp-block-heading">GENERAL INFORMATION ABOUT SILICA ULTRA FINES</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra Fines are produced industrially by crushing</span> <br role="presentation"/><span dir="ltr" role="presentation">The silica content is higher than 99%. </span> <br role="presentation"/><span dir="ltr" role="presentation">The density of 2.65 is measured by pycnometer. </span> <br role="presentation"/><span dir="ltr" role="presentation">Fineness is a statistically calculated value.</span></p>

<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-copie-copie/">Silica Fines D50=18µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silica Fines D50=36µ</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines-copie/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 12:42:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1398</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Silica Ultra-Fines can be used in the control of permeability fineness measuring equipment. The product is nevertheless not referenced in the standard NF EN 196-6. GENERAL INFORMATION ABOUT SILICA ULTRA FINES Silica Ultra Fines are produced industrially by crushing The silica content is higher than 99%. The&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines-copie/">Continue reading <span class="screen-reader-text">Silica Fines D50=36µ</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-copie/">Silica Fines D50=36µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra-Fines can be used in the control of permeability fineness measuring </span><span dir="ltr" role="presentation">equipment. The product is nevertheless not referenced in the standard NF EN 196-6.</span></p>

<h2 class="wp-block-heading">GENERAL INFORMATION ABOUT SILICA ULTRA FINES</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra Fines are produced industrially by crushing</span> <br role="presentation"/><span dir="ltr" role="presentation">The silica content is higher than 99%. </span> <br role="presentation"/><span dir="ltr" role="presentation">The density of 2.65 is measured by pycnometer. </span> <br role="presentation"/><span dir="ltr" role="presentation">Fineness is a statistically calculated value.</span></p>

<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines-copie/">Silica Fines D50=36µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silica Fines D50=61µ</title>
		<link>https://www.standard-sand.com/en/produit/silica-fines/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 12:28:44 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/silica-fines/</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Silica Ultra-Fines can be used in the control of permeability fineness measuring equipment. The product is nevertheless not referenced in the standard NF EN 196-6. GENERAL INFORMATION ABOUT SILICA ULTRA FINES Silica Ultra Fines are produced industrially by crushing.The silica content is higher than 99%. The density&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/silica-fines/">Continue reading <span class="screen-reader-text">Silica Fines D50=61µ</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines/">Silica Fines D50=61µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span></strong><span dir="ltr" role="presentation"><strong>Fineness Measurement</strong> </span></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra-Fines can be used in the control of permeability fineness measuring </span><span dir="ltr" role="presentation">equipment. The product is nevertheless not referenced in the standard NF EN 196-6.</span></p>

<h2 class="wp-block-heading">GENERAL INFORMATION ABOUT SILICA ULTRA FINES</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Silica Ultra Fines are produced industrially by crushing.</span><br role="presentation"/><span dir="ltr" role="presentation">The silica content is higher than 99%. </span> <br role="presentation"/><span dir="ltr" role="presentation">The density of 2.65 is measured by pycnometer. </span> <br role="presentation"/><span dir="ltr" role="presentation">Fineness is a statistically calculated value.</span></p>

<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/silica-fines/">Silica Fines D50=61µ</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Alumina B</title>
		<link>https://www.standard-sand.com/en/produit/alumina-b/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 09:25:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/alumina-b/</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Alumina powder B can be used in the calibration of permeability fineness measuring equipment according to the requirements of standard NF EN 196-6.For the calibration of Blaine’s device, follow the requirements of standard NF EN 196-6, particularly for any temperature corrections. GENERAL CHARACTERISTICS OF ALUMINA B Powders prepared and distributed&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/alumina-b/">Continue reading <span class="screen-reader-text">Alumina B</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/alumina-b/">Alumina B</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Alumina powder B can be used in the calibration of permeability fineness </span><span dir="ltr" role="presentation">measuring equipment according to the requirements of standard NF EN 196-6.</span><br role="presentation"/><span dir="ltr" role="presentation">For the calibration of Blaine’s device, follow the requirements of standard NF EN 196-6, </span><span dir="ltr" role="presentation">particularly for any temperature corrections.</span></p>

<h2 class="wp-block-heading">GENERAL CHARACTERISTICS OF ALUMINA B</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Powders prepared and distributed under the aegis of the Reference Materials </span><span dir="ltr" role="presentation">Department of the National Bureau of Metrology, and supervised by the Competent </span><span dir="ltr" role="presentation">Commission of the AFNOR</span></p>

<figure class="wp-block-table is-style-stripes"><table class="has-fixed-layout"><thead><tr><th class="has-text-align-center" data-align="center">DELIVERY</th><th class="has-text-align-center" data-align="center">Fineness (permeability)</th></tr></thead><tbody><tr><td class="has-text-align-center" data-align="center">Glass Bottle 50g</td><td class="has-text-align-center" data-align="center">10300 cm²/g</td></tr></tbody></table></figure>

<h2 class="wp-block-heading">IMPORTANT RECOMMANDATIONS</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Before using the powder, it is always necessary to pour into a 150 cm³ bottle and shake to re-</span><span dir="ltr" role="presentation">homogenize it. After use, the powder must never be re-used.</span></p>

<h2 class="wp-block-heading">CHEMICAL COMPOSITION</h2>

<p class="wp-block-paragraph">Composition alumina.&#13;
Major impurities: Na2O + Fe2O3 + Si O2 + CaO (moins de 0,3 %).&#13;
<span dir="ltr" role="presentation">Method of preparation: electro-melted product obtained by crushing.</span>&#13;
&#13;
<span dir="ltr" role="presentation">Specific volume mass in g/cm</span><span dir="ltr" role="presentation">³:</span></p>

<ul class="wp-block-list">
<li><span dir="ltr" role="presentation">Specific volume mass in g/cm</span><span dir="ltr" role="presentation">³</span> : 3.95</li>



<li><span dir="ltr" role="presentation">By gas </span><span dir="ltr" role="presentation">pycnometer :</span> 3.84</li>
</ul>
<p>L’article <a href="https://www.standard-sand.com/en/produit/alumina-b/">Alumina B</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Alumina A</title>
		<link>https://www.standard-sand.com/en/produit/alumina-a/</link>
		
		<dc:creator><![CDATA[adm-snlittoral]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 09:24:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/produit/alumina-a/</guid>

					<description><![CDATA[<p>METHOD OF CONTROL AND CALIBRATION Fineness Measurement USAGE Alumina powder A can be used in the calibration of permeability fineness measuring equipment according to the requirements of standard NF EN 196-6. For the calibration of Blaine’s device, follow the requirements of standard NF EN 196-6, particularly for any temperature corrections. GENERAL CHARACTERISTICS OF ALUMINA A&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/alumina-a/">Continue reading <span class="screen-reader-text">Alumina A</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/alumina-a/">Alumina A</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-center wp-block-paragraph"><strong><span dir="ltr" role="presentation">METHOD OF CONTROL AND </span><span dir="ltr" role="presentation">CALIBRATION </span><span dir="ltr" role="presentation">Fineness Measurement</span></strong></p>

<h2 class="wp-block-heading">USAGE</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Alumina powder A can be used in the calibration of permeability fineness </span><span dir="ltr" role="presentation">measuring equipment according to the requirements of standard NF EN 196-6. </span> <br role="presentation"/><span dir="ltr" role="presentation">For the calibration of Blaine’s device, follow the requirements of standard NF EN 196-6, </span><span dir="ltr" role="presentation">particularly for any temperature corrections.</span></p>

<h2 class="wp-block-heading">GENERAL CHARACTERISTICS OF ALUMINA A</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Powders prepared and distributed under the aegis of the Reference Materials </span><span dir="ltr" role="presentation">Department of the National Bureau of Metrology, and supervised by the Competent </span><span dir="ltr" role="presentation">Commission of the AFNOR</span></p>

<figure class="wp-block-table is-style-stripes"><table class="has-fixed-layout"><thead><tr><th class="has-text-align-center" data-align="center">Packaging</th><th class="has-text-align-center" data-align="center">Fineness (permeability)</th></tr></thead><tbody><tr><td class="has-text-align-center" data-align="center">Glass Bottle 50g</td><td class="has-text-align-center" data-align="center">2300 cm²/g</td></tr></tbody></table></figure>

<h2 class="wp-block-heading">IMPORTANT RECOMMANDATIONS</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Before using the powder, it is always necessary to pour into a 150 cm³ bottle and shake to re-</span><span dir="ltr" role="presentation">homogenize it. After use, the powder must never be re-used.</span></p>

<h2 class="wp-block-heading">CHEMICAL COMPOSITION</h2>

<p class="wp-block-paragraph"><span dir="ltr" role="presentation">Chemical composition: Alumine. </span> <br role="presentation"/><span dir="ltr" role="presentation">Major impurities: Na2O + Fe2O3 + Si O2 + CaO (less than 0,1 %</span><span dir="ltr" role="presentation">). </span> <br role="presentation"/><span dir="ltr" role="presentation">Method of preparation: electro-melted product obtained by crushing.</span>&#13;
&#13;
<span dir="ltr" role="presentation">Specific volume mass in g/cm</span><span dir="ltr" role="presentation">³:</span></p>

<ul class="wp-block-list">
<li><span dir="ltr" role="presentation">Specific volume mass in g/cm</span><span dir="ltr" role="presentation">³: 3.95</span></li>



<li><span dir="ltr" role="presentation">By gas </span><span dir="ltr" role="presentation">pycnometer : 3.96</span></li>
</ul>
<p>L’article <a href="https://www.standard-sand.com/en/produit/alumina-a/">Alumina A</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SN200</title>
		<link>https://www.standard-sand.com/en/produit/sn201-100g-copie/</link>
		
		<dc:creator><![CDATA[oppg-leucate]]></dc:creator>
		<pubDate>Fri, 27 Mar 2026 13:59:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1343</guid>

					<description><![CDATA[<p>Composite Fly Ash Cement.</p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/sn201-100g-copie/">SN200</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">METHODS OF CONTROL AND CALIBRATION</h2>



<p class="wp-block-paragraph">This reference material cement allows the control of measuring devices in chemistry and particle size of cement according to the test standard CEN EN 196-6. For the other standards, these reference cements are very useful for regular checks to identify a drift.</p>



<h2 class="wp-block-heading">DELIVERY</h2>



<p class="wp-block-paragraph">The reference cement is offered in 40g bottles. </p>



<p class="wp-block-paragraph">Each cement is delivered with its analysis certificate</p>



<p class="wp-block-paragraph">The certificate of analysis was carried out and checked by the offices of France-Ciments in Clichy</p>



<h2 class="wp-block-heading">PARTICIPATION AND EXECUTION OF THE TESTS</h2>



<p class="wp-block-paragraph">An Inter laboratory testing campaign is organized each year by France-Ciments formerly ATILH. Participating in this campaign are the laboratories of the cement industry in France, Europe and more widely in the world, the laboratories of cement users and research and control centers in the field of construction materials.</p>



<p class="wp-block-paragraph">This participation is mandatory for laboratories accredited by Cofrac for tests on cement. The tests are carried out according to standard methods where they exist and according to current and traditional methods where they do not.</p>



<h2 class="wp-block-heading">STATIC ANALYSIS</h2>



<p class="wp-block-paragraph">Outlier removal is performed at the 98% level by the student test. Reiteration is set at this threshold, to keep only the values related to the &#8220;Normal or Gaussian&#8221; distribution and fully defined by the two parameters: mean and standard deviation. The coefficient of variation symbolized by &#8216;V&#8217; is the ratio between the standard deviation and the mean &#8216;X&#8217;</p>



<h2 class="wp-block-heading">SPECIFIC SURFACE</h2>



<p class="wp-block-paragraph">For the calibration of Blaine’s device, follow the requirements of standard NF EN 196-6 for any temperature corrections. To determine the volume of the compacted layer, it is not essential to use the reference cement, but it must be used systematically:</p>



<ul class="wp-block-list">
<li>After 1000 tries.</li>



<li>In cases using another type of pressure fluid, another type of filter paper, a new gauge tube or a new perforated disc.</li>



<li>In cases of systematic deviations of the secondary reference cement.</li>
</ul>



<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/sn201-100g-copie/">SN200</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KIT XRF-FB Kiln Feed-Clinker-Clinker Oil Well</title>
		<link>https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie-2/</link>
		
		<dc:creator><![CDATA[oppg-leucate]]></dc:creator>
		<pubDate>Fri, 20 Mar 2026 14:05:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1180</guid>

					<description><![CDATA[<p>METHODS OF CONTROL AND CALIBRATION&#160;XRF&#160;with Fuse Bead The SNL is currently developing different calibration kits for your XRF &#38; XRD with three sets of kits Technical Specifications The XRF Fused Beads Reference Materials “Kit 3: kiln feed, clinker and CEM I” consist of 10 homogenized and stable samples that have been rigorously validated through international&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie-2/">Continue reading <span class="screen-reader-text">KIT XRF-FB Kiln Feed-Clinker-Clinker Oil Well</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie-2/">KIT XRF-FB Kiln Feed-Clinker-Clinker Oil Well</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>METHODS OF CONTROL AND CALIBRATION&nbsp;XRF&nbsp;with Fuse Bead</strong></p>



<p class="wp-block-paragraph">The SNL is currently developing different calibration kits for your XRF &amp; XRD with three sets of kits</p>



<ol start="1" class="wp-block-list">
<li>«&nbsp;KIT XRF-FB » enabling to calibrate your XRF on several componants with a large range of measures . 3 versions are available
<ul class="wp-block-list">
<li>SNL-XRF-FB1 for the analysis of CEM I and CEM II/A cements</li>



<li>SNL-XRF-FB CEM II+ for cement analysis with more than 10% additions.</li>



<li>SNL-XRF-FB 3 for the analysis of raw mix and clinker</li>
</ul>
</li>



<li>« KIT XRF-componant » allowing to analyse the same componant on a broad range of measures
<ul class="wp-block-list">
<li>Chlorine</li>



<li>SO3 and Alkalis</li>



<li>P205</li>
</ul>
</li>
</ol>



<h2 class="wp-block-heading"><strong>Technical Specifications</strong></h2>



<p class="wp-block-paragraph">The XRF Fused Beads Reference Materials “Kit 3: kiln feed, clinker and CEM I” consist of 10 homogenized and stable samples that have been rigorously validated through international interlaboratory testing. These samples serve as essential reference materials to ensure and maintain the accuracy of X-ray Fluorescence (XRF) calibrations during routine laboratory operations. They enable continuous monitoring and detection of calibration drift using recommended control charts.&nbsp;</p>



<p class="wp-block-paragraph">The SNL XRF Kit 3 complements the SNL XRF Kits 1 and 2, which are specifically designed for the calibration and validation of XRF fused-bead analyses of cement: Kit 1 covers CEM I and CEM II/A cements containing less than 10% additional constituents, and Kit 2 covers CEM II/B to CEM V (excluding CEM III).</p>



<ul class="wp-block-list">
<li>SNL XRF Kit 3 focuses on the characterization of kiln feed, clinker, and CEM I. It extends the calibration range to cover the growing diversity of materials while maintaining high analytical accuracy and robustness.</li>



<li>Together with the forthcoming SNL XRF Kit 4 (planned for Q1 2027), these reference materials provide a complete and comprehensive portfolio of XRF fused-bead reference materials for the cement industry, covering the entire production process from raw materials to finished cement and supporting the characterization of both conventional and emerging low-carbon cementitious materials.</li>
</ul>



<p class="wp-block-paragraph"><em>Note: SNL XRF Fused Bead Reference Materials are not suitable for use with XRF pressed pellet methods — using them in this context can result in inaccurate calibrations and control values due to significant matrix effect differences, ultimately compromising the reliability of analytical results. It is essential to understand that the mineralogy of each produced and purchased material is highly specific. The fused bead method is the only approach that effectively eliminates mineralogical and matrix-related variability, ensuring accurate and consistent XRF calibration. Please refer to the requirements specified by your XRF equipment suppliers for further guidance.</em></p>



<p class="wp-block-paragraph">Each of the inter-laboratory campaigns involves more than 150 international cement laboratories, as well as XRF suppliers and some accredited laboratories. The logic of the ISO 5725-2: 2019 <em>“Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method”</em> is applied at each step of the elaboration process (excluding Grubbs and Cochran tests, replaced by the &#8220;interquartile method&#8221;).</p>



<p class="wp-block-paragraph"><strong>2- SNL XRF Fused Bead Reference Samples Characteristics</strong></p>



<p class="wp-block-paragraph">The properties of the ten SNL XRF Fused Bead Reference Cement Samples represent the most accurate estimates of their true values. These reference values are derived from the statistical evaluation of results obtained by all participants in the Round Robin Tests, with outliers excluded according to robust statistical methods. Each value is accompanied by an estimate of measurement uncertainty, including both the combined standard uncertainty and the expanded uncertainty (typically at a 95% confidence level).</p>



<p class="wp-block-paragraph">For chemical analysis, it is important to note that the majority of participating laboratories calibrate their instruments using Certified Reference Materials (CRMs) with metrologically traceable certified values. Consequently, the assigned values of the SNL XRF Fused Bead Reference Samples inherit a level of traceability to the International System of Units (SI) through an unbroken metrological chain.</p>



<p class="wp-block-paragraph">The SNL XRF Fused Bead Reference Samples are developed by the principles and guidelines outlined in ISO Guide 35: Reference Materials — Guidance for Characterization and Assessment of Homogeneity and Stability. Comprehensive characterization has been performed using robust analytical methods across multiple international laboratories. Statistical assessments confirm the homogeneity and long-term stability of the samples. The assigned reference values are accompanied by combined and expanded uncertainties, estimated in full compliance with the Guide’s requirements. This rigorous approach ensures that the SNL XRF Fused Bead materials are fit for use as reliable and metrologically traceable reference standards in cement chemical analysis and XRF calibration.</p>



<p class="wp-block-paragraph">Kit 3 consists of 10 fused-bead reference materials, XRF-FB-15 through XRF-FB-24, covering the compositional range typical of raw meal, kiln feed, and clinker matrices.</p>



<p class="wp-block-paragraph">We recommend supplementing this set with 3 additional materials from Kit 2 — XRF-FB-11, XRF-FB-12, and XRF-FB-14 — to extend the concentration range for each analyzed oxide (e.g., CaO, SiO₂, Al₂O₃, Fe₂O₃, MgO, SO₃, K₂O, Na₂O). Broadening the calibration range in this way improves coverage of low- and high-concentration endpoints, reduces extrapolation error, and strengthens the linearity of the regression across the full working range. The objective is to achieve a finer, more robust calibration curve with improved analytical accuracy and precision for routine XRF fused-bead analysis of cement raw materials and clinker.</p>



<p class="wp-block-paragraph">This is a recommendation and should be evaluated against the specific calibration validation criteria (e.g., correlation coefficient, standard error of calibration, RMSEP) applicable to the laboratory&#8217;s quality system.</p>



<p class="wp-block-paragraph"><strong>As received basis:</strong></p>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="1024" height="468" src="https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1024x468.jpg" alt="" class="wp-image-2442" srcset="https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1024x468.jpg 1024w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-300x137.jpg 300w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-768x351.jpg 768w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1536x702.jpg 1536w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1568x717.jpg 1568w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-600x274.jpg 600w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4.jpg 1663w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<p class="wp-block-paragraph"><strong>Ignited basis:</strong><br></p>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="553" src="https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1024x553.png" alt="" class="wp-image-2443" srcset="https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-1024x553.png 1024w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-300x162.png 300w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-768x415.png 768w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4-600x324.png 600w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-4.png 1132w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<p class="wp-block-paragraph"><strong>From As-Received to Ignited Basis</strong></p>



<p class="wp-block-paragraph">Oxide compositions are commonly reported &#8220;as received,&#8221; meaning the percentages include Loss on Ignition (LOI) — the mass lost during heating (typically ~950–1000°C) due to the release of volatile components such as CO2, H2O, and other combustibles. To compare materials on a common, volatile-free basis, results are converted to an &#8220;ignited basis,&#8221; which expresses each oxide as a percentage of the LOI-free (ignited) mass.</p>



<p class="wp-block-paragraph">The conversion is:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>



<ul class="wp-block-list">
<li> Ignited value (%) = As-received value (%) / (1 − LOI_as-received / 100)</li>
</ul>



<p class="wp-block-paragraph">This rescales every oxide upward by the same factor, since removing the LOI mass concentrates the remaining oxides. LOI itself becomes 0% by definition on the ignited basis, and the sum of all other oxides should total close to 100%.</p>



<p class="wp-block-paragraph"><strong>Packaging </strong></p>



<p class="wp-block-paragraph">The KIT consists of a case of 10 samples in hermetically sealed glass containers of about 10 grams and a spatula. The &#8220;<strong>calibration best practices manual</strong>&#8221; is provided with the certificates when ordering. This manual is the exclusive property of SNL and may not be communicated to a third party or purchased separately from the SNL-XRF-FB KIT.</p>



<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie-2/">KIT XRF-FB Kiln Feed-Clinker-Clinker Oil Well</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KIT XRF-FB 2 (CEM II+ to CEM V)</title>
		<link>https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie/</link>
		
		<dc:creator><![CDATA[oppg-leucate]]></dc:creator>
		<pubDate>Fri, 20 Mar 2026 14:00:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.standard-sand.com/?post_type=product&#038;p=1178</guid>

					<description><![CDATA[<p>METHODS OF CONTROL AND CALIBRATION&#160;XRF&#160;with Fuse Bead The SNL is currently developing different calibration kits for your XRF &#38; XRD with three sets of kits TECHNICAL CHARACTERISTICS The XRF Fused Beads Reference Materials “Kit 2: CEM II/A (&#62;10%) to CEM V” (excluding CEM III cement) consist of 7 homogenized and stable cement samples that have&#8230; <a class="more-link" href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie/">Continue reading <span class="screen-reader-text">KIT XRF-FB 2 (CEM II+ to CEM V)</span></a></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie/">KIT XRF-FB 2 (CEM II+ to CEM V)</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>METHODS OF CONTROL AND CALIBRATION&nbsp;XRF&nbsp;with Fuse Bead</strong></p>



<p class="wp-block-paragraph">The SNL is currently developing different calibration kits for your XRF &amp; XRD with three sets of kits</p>



<ol start="1" class="wp-block-list">
<li>«&nbsp;KIT XRF-FB » enabling to calibrate your XRF on several componants with a large range of measures . 3 versions are available
<ul class="wp-block-list">
<li>SNL-XRF-FB1 for the analysis of CEM I and CEM II/A cements</li>



<li>SNL-XRF-FB CEM II+ for cement analysis with more than 10% additions.</li>



<li>SNL-XRF-FB 3 for the analysis of raw mix and clinker</li>
</ul>
</li>



<li>« KIT XRF-componant » allowing to analyse the same componant on a broad range of measures
<ul class="wp-block-list">
<li>Chlorine</li>



<li>SO3 and Alkalis</li>



<li>P205</li>
</ul>
</li>
</ol>



<p class="wp-block-paragraph"><strong>TECHNICAL CHARACTERISTICS</strong></p>



<p class="wp-block-paragraph">The XRF Fused Beads Reference Materials “Kit 2: CEM II/A (&gt;10%) to CEM V” (excluding CEM III cement) consist of 7 homogenized and stable cement samples that have been rigorously validated through international interlaboratory testing. These samples serve as essential reference materials to ensure and maintain the accuracy of X-ray Fluorescence (XRF) calibrations during routine laboratory operations. They enable continuous monitoring and detection of calibration drift using recommended control charts.&nbsp;</p>



<p class="wp-block-paragraph">The SNL XRF Kit 2 complements the SNL XRF Kit 1, which is specifically designed for the calibration and validation of XRF fused-bead analyses of CEM I and CEM II/A cements containing less than 10% additional constituents.</p>



<ul class="wp-block-list">
<li>SNL XRF Kit 2 focuses on the characterization of cements containing 10% or more additional constituents, including other CEM II types and blended cements. It extends the calibration range to cover the growing diversity of low-carbon cement formulations while maintaining high analytical accuracy and robustness.</li>



<li>Together with SNL XRF Kit 3, dedicated to kiln feed and clinker characterization, and the forthcoming SNL XRF Kit 4 (planned for Q1 2027), these reference materials provide a complete and comprehensive portfolio of XRF fused-bead reference materials for the cement industry, covering the entire production process from raw materials to finished cement and supporting the characterization of both conventional and emerging low-carbon cementitious materials.</li>
</ul>



<p class="wp-block-paragraph"><em>Note: SNL XRF Fused Bead Reference Materials are not suitable for use with XRF pressed pellet methods — using them in this context can result in inaccurate calibrations and control values due to significant matrix effect differences, ultimately compromising the reliability of analytical results. It is essential to understand that the mineralogy of each produced and purchased material is highly specific. The fused bead method is the only approach that effectively eliminates mineralogical and matrix-related variability, ensuring accurate and consistent XRF calibration. Please refer to the requirements specified by your XRF equipment suppliers for further guidance.</em></p>



<p class="wp-block-paragraph">Each of the inter-laboratory campaigns involves more than 150 international cement laboratories, as well as XRF suppliers and some accredited laboratories. The logic of the ISO 5725-2: 2019 <em>“Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method”</em> is applied at each step of the elaboration process (excluding Grubbs and Cochran tests, replaced by the &#8220;interquartile method&#8221;).</p>



<p class="wp-block-paragraph">2- SNL XRF Fused Bead Reference Samples Characteristics</p>



<p class="wp-block-paragraph">The properties of the seven SNL XRF Fused Bead Reference Cement Samples represent the most accurate estimates of their true values. These reference values are derived from the statistical evaluation of results obtained by all participants in the Round Robin Tests, with outliers excluded according to robust statistical methods. Each value is accompanied by an estimate of measurement uncertainty, including both the combined standard uncertainty and the expanded uncertainty (typically at a 95% confidence level).</p>



<p class="wp-block-paragraph">For chemical analysis, it is important to note that the majority of participating laboratories calibrate their instruments using Certified Reference Materials (CRMs) with metrologically traceable certified values. Consequently, the assigned values of the SNL XRF Fused Bead&nbsp; Reference Samples inherit a level of traceability to the International System of Units (SI) through an unbroken metrological chain.</p>



<p class="wp-block-paragraph">The SNL XRF Fused Bead Reference Samples are developed and certified by the principles and guidelines outlined in ISO Guide 35: Reference Materials — Guidance for Characterization and Assessment of Homogeneity and Stability. Comprehensive characterization has been performed using robust analytical methods across multiple international laboratories. Statistical assessments confirm the homogeneity and long-term stability of the samples. The assigned reference values are accompanied by combined and expanded uncertainties, estimated in full compliance with the Guide’s requirements. This rigorous approach ensures that the SNL XRF Fused Bead materials are fit for use as reliable and metrologically traceable reference standards in cement chemical analysis and XRF calibration.</p>



<p class="wp-block-paragraph">The Reference Samples provide a significant range for each parameter, as illustrated below.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="736" height="402" src="https://www.standard-sand.com/wp-content/uploads/2026/03/image.png" alt="" class="wp-image-2426" srcset="https://www.standard-sand.com/wp-content/uploads/2026/03/image.png 736w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-300x164.png 300w, https://www.standard-sand.com/wp-content/uploads/2026/03/image-600x328.png 600w" sizes="(max-width: 736px) 100vw, 736px" /></figure>



<p class="wp-block-paragraph">The KIT consists of a case of 7 samples in hermetically sealed glass containers of about 10 grams and a spatula. The calibration best practices manual is provided with the certificates when ordering. This manual is the exclusive property of SNL and may not be communicated to a third party or purchased separately from the SNL-XRF-FB KIT.</p>



<p class="wp-block-paragraph"></p>
<p>L’article <a href="https://www.standard-sand.com/en/produit/kit-xrf-fb-reference-cement-copie-copie/">KIT XRF-FB 2 (CEM II+ to CEM V)</a> est apparu en premier sur <a href="https://www.standard-sand.com/en/">SOCIETE NOUVELLE DU LITTORAL</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
